The medical device regulatory sector incorporates a multitude of terms which may sound confusing. However, in such a heavily regulated industry, chances of committing a mistake should be next to none.

In this blog, we will understand the connotations and references surrounding the two most widely used terms in the medical device industry, i.e. intended use and indications for use. Understanding the difference between these two terms is crucial for those working in the medical device industry. Although the two terms are often used together, they represent distinct concepts with different implications in technical documentation and regulatory compliance. In this article, we explore what exactly they mean, why it is important to distinguish them correctly and what the practical implications are for the drafting of the technical dossier according to Regulation (EU) 2017/745.

What is Meant by Intended Use?

The intended use of the device is defined in Article 2 of the MDR Regulation 2017/745 as:

“the use for which a device is intended according to the data supplied by the manufacturer on the label, in the instructions for use or in promotional or sales materials or statements and as specified by the manufacturer in the clinical evaluation”.

It is the general description of the main purpose of the medical device, as stated by the manufacturer. It defines what the device should do and on what type of patients or conditions it can be used. It may include the function of the device (e.g. monitoring, diagnosis, treatment), the target (e.g. the target population or the target clinical environment), the type of use (e.g. single-use, professional or for lay persons) and the general disease.

In its essence, intended use covers the following important areas:

  • What does the device do?
  • How does the device work?
  • What does the manufacturer claim on their label about the device’s functioning?

What is Meant by Indications for Use?

The indications for use are part of the content that is required for labeling and instructions for use. They are a detailed and specific description of the medical condition, disease, target population, or symptom for which the device is clinically showed, which may include:

  • The circumstances in which someone would use the medical device
  • The specific illness, injury, condition, or disease which will be prevented, diagnosed, or treated by the device
  • Anatomical sites where the device will be used and the duration of its usage
  • The target population for the device (e.g. sex, age and clinical condition);
  • The environment of use.

These are the reasons a patient should use the medical device. As intended use is meant for the manufacturer, indications for use are meant for the patients.

How to Implicate Intended Use and Indications for Use in the Technical file?

Let’s understand different implications in which intended use and indications for use can be used and applied:

  • Intended Use

The intended use of a medical device forms the basis of the risk classification of any medical device. We can understand it by looking at the examples of a tongue depressor and a cardiac pacemaker. Because of its intended use, a tongue depressor would fall into the Class I category, while the cardiac pacemaker would be categorized into Class III.

It also conditions the clinical and non-clinical development plan, as it guides which trials are necessary or not, and determines the type of clinical evidence needed.

The intended use is essential to the MDR regulatory compliance strategy, particularly regarding the applicability or otherwise of general safety and performance requirements.

Finally, it guides the post-marketing surveillance (PMS) and PMCF plan, as, depending on the risk class, more or less documentation may be required.

Some of the following confusions regarding intended use usually exist in the medical device community and the consumers:

  • Intended use means what a medical device the medical device is designed for.
  • Intended use refers to what the medical device could be used for.

The intended use refers to the claims made by the manufacturer on their device’s label. It is all about what the manufacturer ‘”claims” what their device can do.

  • Indication for Use

The regulatory pathway of a medical device depends on Indications for use.Again, we can understand this clearly by looking at the following examples:

A scalpel with the sign of cutting a tissue would be classified as Class I device. However, if this scalpel is showed to be used in retinal surgery, then its category would change to Class III. Such a drastic change happens only because “indications for use” were employed instead of “intended use.”Of course, medical device manufacturers have to remain ever vigilant of such minor details or else they can be met with financial and legal litigations.

Indications for use delimit the target population and clinical scope, thus determining which clinical studies are needed, on which patients’ data are collected and which clinical risks are to be analyzed

They therefore represent the basis for scientific evidence of the clinical benefit of the device and must be supported by solid clinical data.

They condition the marketing claim (you cannot make clinical claims that are not supported by these claims).

They must be consistent with the design, intended use, and claimed performance.

In the table below, the main differences regarding the terms in the exam are listed:

AspectIntended useIndications for Use
ReachGeneralSpecific
TargetDescribe what the device does generallySpecific for what type of conditions/patients the device is clinically showed
Regulatory ImportanceNecessary for the device classification and risk assessmentNecessary for the clinical evaluation and claim marketing approval
Used inTechnical file and labelingLabeling, Instructions for Use and clinical documentation

Strategies to Write Intended Use and Indications for Use

Intended Use

  • Always define your device’s functionality in simple words. Specify what the device is and how does it works;
  • Use regulatory-approved language
  • Do not forget about the risk classification of the device;
  • Keep the device’s intended use uniform across every document, marketing submissions, and product labels;
  • Avoid claiming anything other than the device’s tested and approved capabilities.

Indication for Use

  • State the target population of your device clearly. For instance, mention if your device is to be used by the pediatric, general, or geriatric population;
  • Indicate if the device is meant for short-term, long-term, or hospital use;
  • Make the indications highly focused instead of applying them to the device’s broader functionality;
  • Always ensure that you have used the proper terms to ensure your device’s compliance with regulatory bodies;
  • Avoid overly broad indication;
  • Each indication must be supported by clinical data in the ERC. If you have no data on paediatric patients, do not include them.

Intended Use and Indications for Use – TSQ&E can help!

At TSQ&E, our consultants have a prime knowledge of the different terms used in medical device manufacturing. They are well-aware of the differences made by each, requirements of the concerned regulatory bodies, and safety of the patients.

To learn more, get a consulting session with us.

About the author:
Waqas Imam

S. M. Waqas Imam is associated with TS Quality as a Regional Partner. He is also an ambassador of Medical Device Community. He is an Industrial Engineer by qualification and served the manufacturing industry since 2011. He is also IRCA CQI Lead Auditor of ISO 9001 and other management system standards. He had served as Quality Assurance and Regulatory Affairs Manager in QSA Surgical Pvt. Ltd. and Ultimate Medical Products. He managed requirements of ISO 13485:2003, EU directives, CE marking and FDA. He also served as Expert Blog Writer for 13485Academy and wrote expert articles on various topics of ISO 13485:2016.